Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 1500/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Registered Capital
1000000 RMB
Management System Certification
ISO 9001, ISO 14001
  • Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6
  • Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6
  • Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6
  • Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6
  • Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6
  • Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
SF6
Arc-extinguishing Medium
SF6
Installation
Fixed
Structure
Lbs
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CCC
Transport Package
Wooden Case
Specification
10kg
Trademark
CNKEEYA
Origin
China
HS Code
8536200000
Production Capacity
20000 Units/Per Years

Product Description

Product Description

  • Structural characteristics of FLN36-12 load switch (SF6 load switch):
    1. Load switches and combination devices consist of the same insulated body switch body, their respective spring operating mechanisms, fuse contact holders, and fuse action impact release systems.
    2. The upper and lower bodies are made of epoxy resin injection, forming an inflatable cavity. The common moving contact can rotate to sequentially complete the three working states of "closing, opening, and grounding". Electric closing and opening can be added to the basic hand force spring energy storage operating mechanism to achieve remote control operation for users to choose from.
    3. The position indicator device is directly connected to the transmission shaft of the moving contact, indicating the working position of the moving contact with absolute reliability.
    4. There is a safety diaphragm at the rear of the body. When an accident may occur inside the arc extinguishing chamber, causing excessive pressure, the overpressure gas can break through the diaphragm and be released, thereby ensuring personal safety.
    5. The load switch and grounding switch, as well as the grounding switch and front door, have reliable mechanical interlocks.

Detailed Photos

 

Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6

Product Parameters

Name Value
Switch Contact pressure standard 80-190N
Open tri-phase dissimilar ≤2ms
Close tri-phase dissimilar ≤2ms
Opening average speed 3-6ms
Closing average speed 4-6ms
Mechanical life 10000times

Company Profile

Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6
Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6Cnkeeya Complete Set of Accessories Arc Extinguishing Chamber Sf6

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now